Color Stability of Vita 3D-Master Shade Tabs Following Repeated Disinfection: An In Vitro Study

Volume 4, No. 1, 2027
Received: 2026/07/11, Accepted: 2026/08/22

Authors:

Ali Ismail;

Abstract:

Objectives: This in vitro study evaluated the color stability of VITA 3D-Master shade tabs following repeated disinfection with Peroxan 6% and Desomed 0.5%, compared to a distilled water control. Materials and Methods: Ninety VITA 3D-Master shade tabs representing 10 shades were divided into 3 groups (n = 30): Control, Peroxan 6%, and Desomed 0.5%. Each tab was immersed for 10 minutes per cycle and subjected to 200 disinfection cycles. Color measurements were performed at baseline, 50, 100, 150, and 200 cycles using a VITA Easyshade V spectrophotometer. Color differences were calculated using the CIEDE2000 formula (ΔE00). Data were analyzed using repeated-measures ANOVA and Tukey’s test (α = 0.05). Results: At 200 cycles, mean ΔE00 values were 0.9 ± 0.2 for Control, 2.8 ± 0.4 for Peroxan, and 3.6 ± 0.5 for Desomed. 20% of Peroxan tabs and 100% of Desomed tabs exceeded the clinical acceptability threshold of ΔE00 > 2.7. Repeated-measures ANOVA showed significant main effects for group F(2, 87) = 125.3, p < 0.001, time F(2.88, 250.56) = 98.2, p < 0.001, and group × time interaction F(5.76, 250.56) = 52.1, p < 0.001. Mauchly’s test indicated that the assumption of sphericity was violated for the factor time, χ²(9) = 45.23, p < 0.001, therefore degrees of freedom were corrected using Greenhouse-Geisser estimates ε = 0.72. Post-hoc analysis using Tukey’s test showed significant differences between all groups at each post-disinfection time point (50, 100, 150, and 200 cycles; p < 0.001). Conclusions: Repeated disinfection with Peroxan 6% and Desomed 0.5% caused color changes in VITA 3D-Master shade tabs. Desomed 0.5% reached the clinical acceptability threshold of ΔE00 = 2.7 at 100 cycles and exceeded it thereafter, while Peroxan 6% caused unacceptable changes in 20% of tabs at 200 cycles. These findings suggest that alternative disinfection protocols should be considered to preserve shade matching accuracy in clinical practice. Clinical Significance: Frequent immersion of shade guides in strong oxidizing or phenolic disinfectants may compromise shade matching accuracy.

Keywords:

Color stability, Disinfection, Vita 3D-Master, ΔE, Shade tabs,CIEDE2000, Infection control